China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Med-tronic |
Model Number: | Lifepak LP20 |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | Med-tronic Lifepak LP20 Defibrillator Cover Case In Good Condition | Type: | Lifepak LP20 |
---|---|---|---|
Application: | Medical Equipment,ICU,hospital Device | Warranty: | 90days |
Color: | Green | Key Words: | Defibrillator Cover Case |
Language: | Multiple Languages | Superiority: | Specialized Engineers With 12 Years Of Experience |
Sale Protection: | If We Find Non-human Damage, We Will Be Free For You To Repair Or Returned | Product State: | Run Well |
AC Input Voltage Rate: | 110V—240v | Power Supply Source: | Electric |
Inventory: | In Stock | Method Of Transport: | Expressage |
MOQ: | 1pcs | ||
High Light: | High Pressure Backlight Inverter Board,RD-P-0638 Backlight Inverter Board,SIPF-200A Backlight Inverter Cable |
Med-tronic Physio-Control LIFEPAK 20 LP20 Defibrillator High Pressure Board Backlight Inverter Board and Backlight Inverter cable RD-P-0638 SIPF-200A
► Brief Introduction
The Med-tronic Physio-Control LIFEPAK 20 (LP20) defibrillator ECG interface is a device that allows healthcare professionals to monitor a patient's heart rhythm and provide lifesaving interventions if needed, such as defibrillation or cardioversion. The LP20 has an ECG interface that displays the patient's cardiac rhythm in real-time, allowing healthcare professionals to quickly identify arrhythmias or other abnormalities.
The Backlight Inverter provides power to the internal fluorescent backlight in Active Display. Filtered SW_VBatt is provided to the Backlight Inverter through the User Interface PCB. The output of the inverter is 1000–1500 RMS, open-circuit power to the internal Active Display backlight.
► How to Removed
► Specification
Energy Range | 0 to 450 J |
Load Resistance | 50 Ω ±1% |
Accuracy | ±2% +2 J |
Waveforms | NSR, VF, and Sine Wave |
► Remove and replace.
Check the condition of the following parts and replace as necessary:
To remove the backlight inverter, pull the backlight inverter away from the display bracket and remove excess adhesive.
To remove the W17 Backlight Inverter cable, W15 Active Display cable, or W16 Display Jumper Cable Extender, pull the cable away from its connector on the A08 Backlight Inverter or the A11 Active Display
► Backlight Inverter PCB
► Backlight Inverter Cable
► Company Description
As an expert in medical equipment, we have many years of experience in the production and sale of medical equipment. Our products are of high quality, and have always received unanimous praise from domestic and foreign customers.
We are masters of medical equipment maintenance technology and have always been at the forefront of developing the most advanced kinds of medical equipment and accessories to provide customers and society with the best quality services.
We adhere to the concept of win-win cooperation and are committed to protecting the medical device market, providing perfect preferential prices, excellent quality and reliable services.
Thank you for your time and interest in Med-tronic Physio-Control LIFEPAK 20 LP20 Defibrillator High Pressure Board Backlight Inverter Board and Backlight Inverter cable RD-P-0638 SIPF-200A. If you want to explore more details please let us know.
Contact Person: Rita
Tel: 8618279091952