Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH

1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH

  • 1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH
  • 1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH
  • 1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH
  • 1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH
  • 1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH
1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH
Product Details:
Brand Name: GE
Model Number: 1505-8568-000
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Delivery Time: 3-5 Working Days Product Name: 1505-8568-000 GE Original Respiratory Exhalation Valve Assembly ASSY-MSN, EXH VALVE ASSY Accessory-Ma
Brand: GE Part No: 1505-8568-000
Condition: Original New MOQ: One Piece
Warranty: 90 Days Country Of Origin: USA
Delivery Method: DHL,UPS ,Fedex ,etc
High Light:

1505-8568-000 Patient Monitor Accessories

,

MSN Patient Monitor Accessories

,

Patient Monitor Respiratory Exhalation Valve

GE original Respiratory Exhalation Valve Assembly ASSY-MSN, EXH VALVE ASSY Accessory-Ma 1505-8568-000

 

 

Calibrate the exhalation valve

1. Unable to achieve a pressure of 34 cmH2O

The test indicates a fault without displaying a warning message.

• Make sure the gas supply is connected.

• Identify leaks, repair leaks. and repeat the check

2. If the pressure relief and exhalation valve tests fail and the leak rate is less than 2000, the most likely problem is that the Pexp sensor is not zero:

• Use the service app to fill 34 cmH2O until stabilization. The exhalation or safety valve is then used to relieve the pressure. The Pexp value must return to less than 2 within 250 ms.

If not, re-center and duplicate or replace the Pexp sensor.

3. If this test fails:

A. Use the Service app to verify that the flow rate produced by the FCV is at least 3 L / min. Otherwise:

• FCV calibration.

• Change FCV.

B. Remove the exhaust air flow sensor.

• If inspected Replace the respiratory flow sensor.

C. Remove the exhalation valve assembly. Make sure the voice coil core is clean and dry. Move freely and without restrictions.

D. Replace the exhalation valve assembly.

E. Replace the voice coil module.

If this check fails All ventilation modes will still be available.

 

 

Exhalation valve assembly

1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH 0

 

 

Item Description Part No
 

Exhalation valve assembly (with flow transducer)

 

1505-3848-000
  Exhalation valve assembly (without flow transducer) 1505-8568-000
1 Diaphragm 1505-3224-000
2 Seal 1505-3223-000
3 Housing 1505-3222-000
4 Seal 1505-3257-000
5 Retaining ring 1505-3039-000
6 Flow transducer (includes check valve and screen) 1505-3231-000
7 O-ring 1503-3056-000
8 Plunger 1505-3245-000
9 Spring 1505-3013-000
10 O-ring 1505-3009-000
11 Water trap 1505-3244-000

 

 

 

WARNING: When you follow safety and infection control measures,

Discard the water traps. There may be a risk of infection.

 

To remove the exhalation valve assembly:

1. Disconnect the exhalation flow sensor from the exhalation valve

part.

2. Press the latch as shown below and remove the ventilator exhalation valve assembly.

 

important

Do not remove the exhalation valve assembly without first depressing the release latch. it may damage the case

 

3. Remove the siphon and drain it. Be sure to hold the cup to the O-ring.

4. Lift the diaphragm lip and remove it from the exhalation valve housing. Be sure to save the buffer.

5. Before assembling or using the exhalation valve assembly, follow these steps:

• Check for cracks, discoloration, or other damage

• Replace worn parts

• Perform system checks

 

 

Connecting and removing the exhalation valve housing

 

The exhalation valve housing contains the exhalation flow sensor and the water manifold.

1. To install the cover, insert the cover tabs (2) into the slots (1), then press the cover into place.

• You will hear a click, then pull gently on the cover to make sure it snaps into place.

1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH 1

2. To remove the cover, press the latch to release the exhalation valve cover, then remove the ventilator cover.

1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH 2

3. Unscrew the siphon to remove it from the housing for emptying or cleaning.

1505-8568-000 Patient Monitor Accessories Respiratory Exhalation Valve Assembly MSN EXH 3

 

If you're interested in 1505-8568-000 GE original Respiratory Exhalation Valve Assembly ASSY-MSN, EXH VALVE ASSY Accessory-Ma,feel free to contact us .Thank you .

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.